Norden Category 6 UTP Cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair balance providing excellent EMC, minimizing radiation, maximizing noise immunity and providing high alien cross talk...
Overview Specifications Ordering Information
|
|
COMPLIANCEIEEE 802.af,IEEE 802.3at for PoE applications ISO/IEC-11801, Class E IEC 61156-5: Category 6 |
|
Conductor Material |
Solid Bare Electrolytic Grade Copper |
|
Conductor Size |
0.55 mm, 23 AWG |
|
Conductor Construction |
Solid |
|
Insulation Material |
HDPE |
|
Insulation Diameter |
1.02 ± 0.5 mm |
|
Rip Cord |
Yes |
|
Inner Sheath Material |
FR-PVC |
|
Inner Sheath Thickness |
0.80±0.2 mm |
|
Armored Material |
Galvanized Iron Wire |
|
Armouring Thickness |
0.60mm |
|
Armored Material Coverage |
≥65% |
|
Fire Rating |
IEC 60332-1 |
|
Outer Sheath Material |
FR-PVC (UV Resistant) |
|
Outer Sheath External O.D. |
9.40 ± 0.50 mm |
|
Outer Sheath Color |
Black |
|
Frequency Range |
1 - 250 MHz |
|
Impedance |
100±15 Ω |
|
DC Resistance |
9.38 Ω/100m |
|
Max. Resistance Unbalance |
5% max. |
|
Mutual Capacitance |
5.6 nf/100 mtr |
|
Capacitance Unbalance |
3.3 pF max. |
|
Velocity of Propagation |
69 % nom. |
|
Propagation Delay Skew |
45 ns/100m max. |
|
Tensile Strength (Mpa) |
≥10.0 (Before Aging) ≥8.0 (After Aging) |
|
Elongation(%) |
≥350 (Before Aging) ≥300 (After Aging) |
|
Min. Bend Radius |
9.40 x O.D |
|
Max. Operating Temperature |
-20 °C +75 °C |
Cat. 6 Screened Pair Horizontal Cables*
| Freq. MHz | Attenuation dB/100 m @ 20°C | NEXT dB | PSNEXT dB | ACRF (dB@100 m) min. | PS.ACRF (dB@100 m ) min. | Return Loss (dB/100 m) |
| 1 | 2.1 | 65.0 | 62.0 | 63.3 | 60.3 | 19 |
| 4.0 | 4 | 63.0 | 60.5 | 51.2 | 48.2 | 19 |
| 8.0 | 5.7 | 58.2 | 55.6 | 45.2 | 42.2 | 19 |
| 10.0 | 6.3 | 56.6 | 54 | 43.3 | 40.3 | 19 |
| 16.0 | 8 | 53.2 | 50.6 | 39.2 | 36.2 | 18 |
| 20.0 | 9 | 51.6 | 49.0 | 37.2 | 34.2 | 17.5 |
| 25.0 | 10.1 | 50.0 | 47.3 | 35.3 | 32.3 | 17 |
| 31.25 | 11.4 | 48.4 | 45.7 | 33.4 | 30.4 | 16.5 |
| 62.5 | 16.5 | 43.4 | 40.6 | 27.3 | 20.3 | 14 |
| 100 | 21.3 | 39.9 | 37.1 | 23.3 | 20.3 | 12 |
| 200 | 31.5 | 34.8 | 31.9 | 17.2 | 14.2 | 9 |
| 250 | 35.9 | 33.1 | 30.2 | 15.3 | 12.3 | 8 |
*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
| Part Number | Description |
Standard Length |
|
113-20D57104X |
Category 6 U/UTP Double Jacket Galvanized Iron Wire Armoured Anti-Termite External Cable FR-PVC (UV Resistant) |
305 mtr |
X: BK(Black), GY(Gray)