Norden Category 6 U/FTP cables exceed Category 6/Class E specification. It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 U/FTP cables are UL listed CM, CMX, CMR & CMP.Data integrity is one of the most essential network...
Overview Specifications Ordering Information
![]() |
COMPLIANCEIEEE 802.af,IEEE 802.3at for PoE applications |
| Product Sequence | Premium |
| Product Type | Twisted Pair Cable |
|
Conductor Material |
Bare Copper |
|
Conductor Size |
0.57 mm, 23 AWG |
|
Conductor Construction |
Solid |
|
Insulation Material |
SFS PE |
|
Insulation Diameter |
1.36 mm nom. |
|
Rip Cord |
Yes |
|
Colour Code |
Per TIA/EIA 568-B |
|
In. Shield Material |
Aluminium/Polyester Foil |
|
In. Shield Design |
Aluminium Face Outwards |
|
Overall Drain-Wire Material |
N/A |
|
Overall Drain-Wire Size |
N/A |
|
Total Number of Wires |
8 |
|
Outer Jacket |
LSZH (Low Smoke Zero Halogen) or PVC |
|
Outer Jacket Thickness & Ex. Diameter |
0.60±0.05 mm, 7.4±0.4 mm |
|
Outer Jacket Colour |
Per Requirement |
|
Marking |
Per Requirement |
|
Frequency Range |
1 - 250 MHz |
|
Impedance |
100 Ω |
|
Coupling Attenuation |
85 dB min @ 30-100 MHz 85-20 Log (f/100) @100-250 MHz |
|
DC Resistance |
73 Ω/km nom. |
|
Max. Resistance Unbalance |
2 % |
|
Capacitance Unbalance |
3.3 pF max. |
|
Velocity of Propagation |
80 % nom. |
|
Propagation Delay Skew |
35 ns/100m max. |
|
Dielectric Strength |
700 V/minute |
|
Dielectric Strength to Shield |
700 V/minute |
|
Min. Insulation Resistance |
5 GΩ•km |
|
Max. Tensile Strength - Short Term |
150 N |
|
Min. Bend Radius |
70 mm |
|
Max. Operating Temperature |
-20 °C +70 °C |
Cat. 6 Screened Pair Horizontal Cables*
| Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PS.ACRF dB |
|
1 |
2.0 |
80.0 |
78.0 |
27.0 |
81.8 |
77.8 |
|
4 |
3.8 |
75.0 |
72.8 |
30.0 |
76.8 |
73.8 |
|
10 |
6.0 |
71.0 |
69.0 |
30.0 |
70.0 |
67.8 |
|
20 |
8.5 |
62.0 |
60.2 |
30.0 |
58.8 |
55.8 |
|
31.25 |
10.4 |
60.9 |
58.9 |
28.6 |
56.8 |
53.3 |
|
100 |
19.8 |
54.0 |
52.0 |
26.0 |
47.8 |
44.8 |
|
150 |
24.7 |
50.7 |
48.7 |
25.1 |
43.3 |
40.3 |
|
200 |
29.0 |
48.1 |
46.1 |
23.8 |
38.8 |
35.8 |
|
250 |
32.8 |
46.3 |
44.3 |
22.0 |
36.8 |
33.8 |
*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
| Part Number | Description | Standard Length |
| 113-11001304X | Category 6 U/FTP 4 Pair Cable PVC | 305 mtr |
| 113-11002304X | Category 6 U/FTP 4 Pair Cable LSZH | 305 mtr |